Attic Temperature Differential

Digital Differential Outlet Thermostat For Attic Ventilation Digital Differential Thermostat For Heating Cooling Ventilation And Humidity Control In Attic Roof Basement Td320 89 99 Auber Instruments Inc Temperature Control Solutions For

Digital Differential Outlet Thermostat For Attic Ventilation Digital Differential Thermostat For Heating Cooling Ventilation And Humidity Control In Attic Roof Basement Td320 89 99 Auber Instruments Inc Temperature Control Solutions For

Fsec Pf 336 98

Fsec Pf 336 98

Attic Ventilation Energy Smart Home Performance

Attic Ventilation Energy Smart Home Performance

Fsec Pf 336 98

Fsec Pf 336 98

Rr 0917 Measurement Of Attic Temperatures And Cooling Energy Use In Vented And Sealed Attics In Las Vegas Nevada Building Science Corporation

Rr 0917 Measurement Of Attic Temperatures And Cooling Energy Use In Vented And Sealed Attics In Las Vegas Nevada Building Science Corporation

Reduce Heating Cost Using Solar Heated Attic Air And Our Solar Space Heating System

Reduce Heating Cost Using Solar Heated Attic Air And Our Solar Space Heating System

Reduce Heating Cost Using Solar Heated Attic Air And Our Solar Space Heating System

And remember that is with only a 2f degree differential.

Attic temperature differential.

Heat flow through the insulation is roughly proportional to the temperature differance. After sunset the attic temperatures continue this trend. Ideal attic temperatures shouldn t be more than 10 to 20 degrees hotter than outside temperatures. What should the attic temperature be relative to the outside and house temperatures assuming a new supposedly well insulated house.

These images came from a presentation danny parker gave pdf on fsec s cool roof research the third graph shows attic temperatures from the middle of the attic for several different types of roofing as well as a sealed attic. R value from outdoors to attic 1 u. Temperature difference 35 71 41 67 70 0. A good sign is when you open your attic in the winter and you don t see any frost on the nails poking through.

Attic temperatures track right at or within a few degrees of outdoor ambient temperatures. The white roof lowered the attic temperature by about 20 f. If the attic surfaces cool down 10f then the energy is 5x as great. Eave space temperature 0 f outdoors calculated difference.

Warner is right that the attic should be close to the outside temp. In this situation i check the temp drop at the unit. If your attic soars above 100 degrees and reaches the 150 mark its time to consult professionals. I have seen duct with r 6 insulation in a vented attic gain 2 3 degrees every 10 feet of run especially if it runs near the peak of the roof.

The frost is frozen condensation from the warm air meeting the cold air and not ventilating if that. January 8 2010 5 15pm text size. Depending on the location of the ducts and air handling equipment the temperature at the grill and vents may vary a great deal. If you do a good job with attic fans and get the attic temp down to 5f over ambinet 105f then you are dealing with a 27f temperature gradient.

If you are keeping your house at 78f in 100f ambient and the attic is 125f then you have a 47f temp gradient. With 60 f in the eave space on the coldest day there is no risk of pipes freezing and minimal waste heat loss from the heating system ducts.

Differential Temperature Controller Attic Heat Harvester Performance

Differential Temperature Controller Attic Heat Harvester Performance

The 1 Reason Power Attic Ventilators Don T Help

The 1 Reason Power Attic Ventilators Don T Help

From The Q And A Nuts Volts Magazine

From The Q And A Nuts Volts Magazine

The Importance Of Ventilation

The Importance Of Ventilation

Source : pinterest.com